General

 
Max No of transmitters per system31
Max No of receivers per system40
Number of RF channels per system
(multiple systems supported)
1

Equalisation

 
Band Width300Hz-3Hz
Accuracy
- Amplitude
- Phase 

± 1 dB
± 5º
Equalisation
- End to end loss @ 1 kHz
- Delay between two sites

16 dB
50mSec (manual)
5mSec (automatic)
Amplitude response+2 to -6 dB

CTCSS

 
Any Single EIA Group A, B or C Tone, 
SynchronisationGPS 1ppS
Max Level2 Vp-p, 5k Ohm load
(Selectable) Reverse Burst
200 ms Duration, 180 ms @ 120º
200 ms Duration, 150 ms @ 180º

Distribution System Signalling

Control to Remote SiteIdle tone
Remote to Control SiteIdle Tone
Note: E & M signalling is supported in the Remote to Centarl direction only (solar installations), this option will not allow link/site monitoring in this direction.

Link System Levels

Control Site to Remote Site
Traffic: -12 dBm
Signalling: -16 dBm
Remote Site to Control Site
Traffic: -10 dBm
Signalling: -16 dBm